GBDE
Switching Test Probe with Easy-Replacement System 160 mil / 4.0 mm - Switching Travel 4.0 mm

Series 3011/2GS



- Switching test probe for the cable harness test
- Threaded type
- Easy-replacement system
- Replacement without soldering
- Switching travel 4.0 mm
- Soldering temperature max 300°C



  • Technical Data
  • Tips
  • Technical Drawings
  • How to Order
Mechanical Data    
Center 4.00 mm/160 mil  
Temperature Range -30 °C - +120 °C  
Full Travel 5.00 mm  
Working Travel 4.00 mm  
Switching Travel 4.00 mm  
Pre-Loaded Spring Force 0.12/ 0.25/ 0.30/ 0.40/ 0.60/ 1.40/ 1.80/ 1.70/ 2.00/ 2.70/ 2.00/ 5.00/ 4.00 N  
Spring Force at Working Travel 0.25/ 0.75/ 1.30/ 1.80/ 3.00/ 6.50/ 7.00/ 8.00/ 8.50/ 9.00/ 9.50/ 12.00/ 12.50 N  
Spring Force at Switching Travel 0.25/ 0.75/ 1.30/ 1.80/ 3.00/ 6.50/ 7.00/ 8.00/ 8.50/ 9.00/ 9.50/ 12.00/ 12.50 N  
Electrical Data    
Receptacle-Plunger  
Max. Current Rating 5.0 A  
Typical Continuity Resistance ≤ 15 mOhm  
Pin-Plunger  
Max. Current Rating 1.0 A  
Typical Continuity Resistance ≤ 50 mOhm  
Typical Insulating Voltage 1000 V  
Materials    
Barrel Brass, gold plated  
Spring Spring Steel, gold plated  
Plunger Steel  
Receptacle Brass, gold plated  
Recommended Diameter of Drill    
H 3011/GWR5 (/R /RK)
HP 2361.1 (Trolitax) 3.02 mm  
HGW 2372 (Glass filled Material) 3.04 mm  
H 3011/K (/5K)
HP 2361.1 (Trolitax) 3.01 mm  
HGW 2372(Glass filled Material) 3.02 mm  
Available Screw Tools    
Article Designation max. Tip Diameter  
WFS 1060/G-4.0-3.0 3.0
WFS 1060/G-5.0-4.0-Z 4.0
WFS 1060/G-6.0-5.0-Z 5.0

back